Nokta-detectors Fors CoRe Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Desporto e lazer Nokta-detectors Fors CoRe. Nokta detectors Fors CoRe User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 2 - DETECTORS

152346TargetIDGeneral Search7645GENIf you press and hold any of these switches at startup, system information including software version and the seria

Página 3 - TABLE OF CONTENTS

123451 2354TargetDepth7628GroundBalancePump The Coil2060The ground balance value during ground balancing and the target ID during searching instantly

Página 4 - IMPORTANTIMPORTANT

The menu screen allows you to access all the FORS CoRe settings. You can go to the menu screen by pressing one of the up/down/+/- switches while on th

Página 5 - PARTS and ASSEMBLY

You can customize ID Masking according to your needs. Each mode has its own default ID Masking value in the menu. When you change the mode, the ID Mas

Página 6

The brightness level of the LCD panel on the system box aects power consumption a lot. Therefore, the backlight illuminates during menu access and gr

Página 7 - CORRECT WAY OF SWEEPING

IMPORTANT DETAILS ABOUT MENU USAGE:* If no button is pressed for a few seconds after accessing the menu, the device will go back to the main screen. I

Página 8 - BATTERIES

GENERAL SEARCH MODE (GEN):Sometimes referred to as the ''All Metal'' mode, this is the deepest mode of the device. Dierent than t

Página 9 - CONTROLS

Metal detectors work on the principle of conductivity and all metals are conductive. On the other hand, soil itself has a certain degree of conductive

Página 10 - DEVICE INTRODUCTION

One of the following may happen as a result of improper ground balancing: -The device gives a signal whe

Página 11 - NUMERIC DISPLAY

One of the following may happen as a result of improper ground balancing: -The device gives a signal whe

Página 12

Thank you for choosing and purchasing our Nokta FORS CoRe detector.FORS CoRe, developed by Nokta's expert engineering team experienced in metal d

Página 13

4. Continue the above process until the sound is eliminated. If the sound is not completely eliminated, then you can fine tune. For fine tuning, follo

Página 14

GROUND BALANCE VALUE:The ground balance value indicates the type of ground. Some typical ground types are as follows:0-25 Wet salt water or w

Página 15

Adjusting these two settings correctly is critical for the device to work at its best performance and without noise. It is possible to obtain an avera

Página 16 - SEARCH MODES

Hot Rocks and Mineralized SoilsHot rocksIron rocksSalty and alkali soils 0-5 / 95-995-2525-35Non-ferrous MetalsGold nuggets and coinsSilver and leadBr

Página 17 - GROUND BALANCE

Brown Area: Hot rocks Blue Area: Ferrous metals, iron rocks, salty and alkali soilsYellow Area: Gold, folio, soda cans, pull-tabs, some coins etc.Red

Página 18 - Pump The Coil

Pinpointing is to determine the center or the exact location of a detected target.FORS CoRe operates on the principle of motion. This means that you m

Página 19

The device gives an estimated depth reading based on signal strength in the pinpoint mode. When the pinpoint button is pressed and the target is appro

Página 20

Magnetic Mineralization level ranges from 0-99 and is displayed in the Magnetic Mineralization Indicator on the right side of the main screen. This me

Página 21

In discrimination modes, positive hot rocks will give a typical metal sound again. Negative hot rocks will not give any sound in these modes (except f

Página 22 - SENSITIVITY and THRESHOLD

In reality a simple principle can save you a lot of time: ''If the target encountered is not a rock, it can be metal''.The key to

Página 23 - TARGET ID and ID MASKING

TABLE OF CONTENTSFORS / Page 2www.noktadetectors.comNOKTA DETECTORSWARNINGS ...

Página 24

At the bottom of the LCD panel, on the main screen, messages will appear if any. If there is no message, the present search mode name will be displaye

Página 25 - PINPOINT

The technical settings of the device (Mode, Ground Balance, Sensitivity, Threshold, and ID Masking, Frequency) come with their factory default values

Página 26 - DEPTH INDICATION

Operating PrincipleOperating FrequencyMetal IdentificationSearch ModesAudio FrequenciesAudio DiscriminationGround BalanceGround TrackingPinpointFreque

Página 28 - METALS UNDER HOT ROCKS

LEGAL WARNINGS► When using the device, comply with all applicable laws and regulations. Do not use the device in private premises, historic sites

Página 29

PARTS and ASSEMBLY127743568107Attach the right/left armrest components to the S-rod with the bolts and nuts as seen in the picture. Do not tighten the

Página 30 - MESSAGES

1132324PARTS and ASSEMBLY1)To attach the telescopic shaft to the S-rod, first loosen the twist lock. 2)By holding the metal pin pressed, insert the te

Página 31 - FACTORY and STARTUP SETTINGS

CORRECT WAY OF HOLDINGCORRECT WAY OF SWEEPINGShaft height is wrong.It is very important to adjust the shaft to your height correctly to be able to sea

Página 32 - TECHNICAL SPECIFICATIONS

TargetIDGeneral Search7645GENROCK IRONTargetIDGeneral Search7645GENTargetIDLow Battery00- -ROCK IRONTargetIDGeneral Search7645GENThe device comes with

Página 33

15 7 6432DEVICE INTRODUCTION(1) POWER SWITCH:To turn on the device, press the power switch to (1) position. The startup tone will be heard and after t

Comentários a estes Manuais